power: supply: bq25890: Call power_supply_changed() after updating input current...
authorHans de Goede <hdegoede@redhat.com>
Sat, 15 Apr 2023 18:23:40 +0000 (20:23 +0200)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Tue, 30 May 2023 13:17:25 +0000 (14:17 +0100)
commit ad3d9c779b1f09f3f3a6fefd07af407c7bc7c9a7 upstream.

The bq25892 model relies on external charger-type detection and once
that is done the bq25890_charger code will update the input current
and if pumpexpress is used also the input voltage.

In this case, when the initial power_supply_changed() call is made
from the interrupt handler, the input settings are 5V/0.5A which
on many devices is not enough power to charge (while the device is on).

On many devices the fuel-gauge relies in its external_power_changed
callback to timely signal userspace about charging <-> discharging
status changes. Add a power_supply_changed() call after updating
the input current or voltage. This allows the fuel-gauge driver
to timely recheck if the battery is charging after the new input
settings have been applied and then it can immediately notify
userspace about this.

Fixes: 48f45b094dbb ("power: supply: bq25890: Support higher charging voltages through Pump Express+ protocol")
Fixes: eab25b4f93aa ("power: supply: bq25890: On the bq25892 set the IINLIM based on external charger detection")
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/power/supply/bq25890_charger.c

index abd7f7c2cbb75a82049b91dde2346906fa9bcba0..75cf2449abd97173750dc7486e6e7c1dee78fa41 100644 (file)
@@ -775,6 +775,7 @@ static void bq25890_charger_external_power_changed(struct power_supply *psy)
        }
 
        bq25890_field_write(bq, F_IINLIM, input_current_limit);
+       power_supply_changed(psy);
 }
 
 static int bq25890_get_chip_state(struct bq25890_device *bq,
@@ -1106,6 +1107,8 @@ static void bq25890_pump_express_work(struct work_struct *data)
        dev_info(bq->dev, "Hi-voltage charging requested, input voltage is %d mV\n",
                 voltage);
 
+       power_supply_changed(bq->charger);
+
        return;
 error_print:
        bq25890_field_write(bq, F_PUMPX_EN, 0);