+* Copyright (C) 2013 - 2014 Bosch Sensortec GmbH
+*
+* bme280.c
+* Date: 2014/12/12
+* Revision: 2.0.3(Pressure and Temperature compensation code revision is 1.1
+* and Humidity compensation code revision is 1.0)
+*
+* Usage: Sensor Driver file for BME280 sensor
+*
+****************************************************************************
+* License:
+*
+* Redistribution and use in source and binary forms, with or without
+* modification, are permitted provided that the following conditions are met:
+*
+* Redistributions of source code must retain the above copyright
+* notice, this list of conditions and the following disclaimer.
+*
+* Redistributions in binary form must reproduce the above copyright
+* notice, this list of conditions and the following disclaimer in the
+* documentation and/or other materials provided with the distribution.
+*
+* Neither the name of the copyright holder nor the names of the
+* contributors may be used to endorse or promote products derived from
+* this software without specific prior written permission.
+*
+* THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
+* CONTRIBUTORS "AS IS" AND ANY EXPRESS OR
+* IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
+* WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
+* DISCLAIMED. IN NO EVENT SHALL COPYRIGHT HOLDER
+* OR CONTRIBUTORS BE LIABLE FOR ANY
+* DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY,
+* OR CONSEQUENTIAL DAMAGES(INCLUDING, BUT NOT LIMITED TO,
+* PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
+* LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
+* HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY,
+* WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
+* (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN
+* ANY WAY OUT OF THE USE OF THIS
+* SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE
+*
+* The information provided is believed to be accurate and reliable.
+* The copyright holder assumes no responsibility
+* for the consequences of use
+* of such information nor for any infringement of patents or
+* other rights of third parties which may result from its use.
+* No license is granted by implication or otherwise under any patent or
+* patent rights of the copyright holder.
+**************************************************************************/
+
+#include "bme280.h"
+static struct bme280_t *p_bme280; /**< pointer to BME280 */
+
+/*!
+ * @brief This function is used for initialize
+ * the bus read and bus write functions
+ * and assign the chip id and I2C address of the BME280 sensor
+ * chip id is read in the register 0xD0 bit from 0 to 7
+ *
+ * @param bme280 structure pointer.
+ *
+ * @note While changing the parameter of the bme280_t
+ * @note consider the following point:
+ * Changing the reference value of the parameter
+ * will changes the local copy or local reference
+ * make sure your changes will not
+ * affect the reference value of the parameter
+ * (Better case don't change the reference value of the parameter)
+ *
+ *
+ *
+ *
+ * @return results of bus communication function
+ * @retval 0 -> Success
+ * @retval -1 -> Error
+ *
+ *
+*/
+BME280_RETURN_FUNCTION_TYPE bme280_init(struct bme280_t *bme280)
+{
+ /* used to return the communication result*/
+ BME280_RETURN_FUNCTION_TYPE com_rslt = ERROR;
+ u8 v_data_u8 = BME280_ZERO_U8X;
+ p_bme280 = bme280;
+ /* assign BME280 ptr */
+ com_rslt = p_bme280->BME280_BUS_READ_FUNC(p_bme280->dev_addr,
+ BME280_CHIP_ID_REG, &v_data_u8, BME280_ONE_U8X);
+ /* read Chip Id */
+ p_bme280->chip_id = v_data_u8;
+
+ bme280_get_calib_param();
+ /* readout bme280 calibparam structure */
+ return com_rslt;
+}
+/*!
+ * @brief This API is used to read uncompensated temperature
+ * in the registers 0xFA, 0xFB and 0xFC
+ * @note 0xFA -> MSB -> bit from 0 to 7
+ * @note 0xFB -> LSB -> bit from 0 to 7
+ * @note 0xFC -> LSB -> bit from 4 to 7
+ *
+ * @param v_uncomp_temperature_s32 : The value of uncompensated temperature
+ *
+ *
+ *
+ * @return results of bus communication function
+ * @retval 0 -> Success
+ * @retval -1 -> Error
+ *
+ *
+*/
+BME280_RETURN_FUNCTION_TYPE bme280_read_uncomp_temperature(
+s32 *v_uncomp_temperature_s32)
+{
+ /* used to return the communication result*/
+ BME280_RETURN_FUNCTION_TYPE com_rslt = ERROR;
+ /* Array holding the MSB and LSb value
+ a_data_u8r[0] - Temperature MSB
+ a_data_u8r[1] - Temperature LSB
+ a_data_u8r[2] - Temperature LSB
+ */
+ u8 a_data_u8r[ARRAY_SIZE_THREE] = {
+ BME280_ZERO_U8X, BME280_ZERO_U8X, BME280_ZERO_U8X};
+ /* check the p_bme280 structure pointer as NULL*/
+ if (p_bme280 == BME280_NULL) {
+ return E_BME280_NULL_PTR;
+ } else {
+ com_rslt = p_bme280->BME280_BUS_READ_FUNC(
+ p_bme280->dev_addr,
+ BME280_TEMPERATURE_MSB_REG,
+ a_data_u8r, BME280_THREE_U8X);
+ *v_uncomp_temperature_s32 = (s32)(((
+ (u32) (a_data_u8r[INDEX_ZERO]))
+ << SHIFT_LEFT_12_POSITION) |
+ (((u32)(a_data_u8r[INDEX_ONE]))
+ << SHIFT_LEFT_4_POSITION)
+ | ((u32)a_data_u8r[INDEX_TWO] >>
+ SHIFT_RIGHT_4_POSITION));
+ }
+ return com_rslt;
+}
+/*!
+ * @brief Reads actual temperature from uncompensated temperature
+ * @note Returns the value in 0.01 degree Centigrade
+ * Output value of "5123" equals 51.23 DegC.
+ *
+ *
+ *
+ * @param v_uncomp_temperature_s32 : value of uncompensated temperature
+ *
+ *
+ * @return Returns the actual temperature
+ *
+*/
+s32 bme280_compensate_T_int32(s32 v_uncomp_temperature_s32)
+{
+ s32 v_x1_u32r = BME280_ZERO_U8X;
+ s32 v_x2_u32r = BME280_ZERO_U8X;
+ s32 temperature = BME280_ZERO_U8X;
+
+ v_x1_u32r = ((((v_uncomp_temperature_s32
+ >> SHIFT_RIGHT_3_POSITION) - ((s32)
+ p_bme280->cal_param.dig_T1 << SHIFT_LEFT_1_POSITION))) *
+ ((s32)p_bme280->cal_param.dig_T2))
+ >> SHIFT_RIGHT_11_POSITION;
+ v_x2_u32r = (((((v_uncomp_temperature_s32
+ >> SHIFT_RIGHT_4_POSITION) -
+ ((s32)p_bme280->cal_param.dig_T1))
+ * ((v_uncomp_temperature_s32 >> SHIFT_RIGHT_4_POSITION) -
+ ((s32)p_bme280->cal_param.dig_T1)))
+ >> SHIFT_RIGHT_12_POSITION) *
+ ((s32)p_bme280->cal_param.dig_T3))
+ >> SHIFT_RIGHT_14_POSITION;
+ p_bme280->cal_param.t_fine = v_x1_u32r + v_x2_u32r;
+ temperature = (p_bme280->cal_param.t_fine
+ * BME280_FIVE_U8X + BME280_ONE_TWENTY_EIGHT_U8X)
+ >> SHIFT_RIGHT_8_POSITION;
+ return temperature;
+}
+/*!
+ * @brief Reads actual temperature from uncompensated temperature
+ * @note Returns the value with 500LSB/DegC centred around 24 DegC
+ * output value of "5123" equals(5123/500)+24 = 34.246DegC
+ *
+ *
+ * @param v_uncomp_temperature_s32: value of uncompensated temperature
+ *
+ *
+ *
+ * @return Return the actual temperature as s16 output
+ *
+*/
+s16 bme280_compensate_T_int32_sixteen_bit_output(
+s32 v_uncomp_temperature_s32)
+{
+ s16 temperature = BME280_ZERO_U8X;
+ bme280_compensate_T_int32(v_uncomp_temperature_s32);
+ temperature = (s16)((((
+ p_bme280->cal_param.t_fine
+ - BME280_TEMP_1_2_2_8_8_0_DATA)
+ * BME280_TWENTY_FIVE_U8X)
+ + BME280_ONE_TWENTY_EIGHT_U8X)
+ >> SHIFT_RIGHT_8_POSITION);
+
+ return temperature;
+}
+/*!
+ * @brief This API is used to read uncompensated pressure.
+ * in the registers 0xF7, 0xF8 and 0xF9
+ * @note 0xF7 -> MSB -> bit from 0 to 7
+ * @note 0xF8 -> LSB -> bit from 0 to 7
+ * @note 0xF9 -> LSB -> bit from 4 to 7
+ *
+ *
+ *
+ * @param v_uncomp_pressure_s32 : The value of uncompensated pressure
+ *
+ *
+ *
+ * @return results of bus communication function
+ * @retval 0 -> Success
+ * @retval -1 -> Error
+ *
+ *
+*/
+BME280_RETURN_FUNCTION_TYPE bme280_read_uncomp_pressure(
+s32 *v_uncomp_pressure_s32)
+{
+ /* used to return the communication result*/
+ BME280_RETURN_FUNCTION_TYPE com_rslt = ERROR;
+ /* Array holding the MSB and LSb value
+ a_data_u8[0] - Pressure MSB
+ a_data_u8[1] - Pressure LSB
+ a_data_u8[2] - Pressure LSB
+ */
+ u8 a_data_u8[ARRAY_SIZE_THREE] = {
+ BME280_ZERO_U8X, BME280_ZERO_U8X, BME280_ZERO_U8X};
+ /* check the p_bme280 structure pointer as NULL*/
+ if (p_bme280 == BME280_NULL) {
+ return E_BME280_NULL_PTR;
+ } else {
+ com_rslt = p_bme280->BME280_BUS_READ_FUNC(
+ p_bme280->dev_addr,
+ BME280_PRESSURE_MSB_REG,
+ a_data_u8, BME280_THREE_U8X);
+ *v_uncomp_pressure_s32 = (s32)((
+ ((u32)(a_data_u8[INDEX_ZERO]))
+ << SHIFT_LEFT_12_POSITION) |
+ (((u32)(a_data_u8[INDEX_ONE]))
+ << SHIFT_LEFT_4_POSITION) |
+ ((u32)a_data_u8[INDEX_TWO] >>
+ SHIFT_RIGHT_4_POSITION));
+ }
+ return com_rslt;
+}
+/*!
+ * @brief Reads actual pressure from uncompensated pressure
+ * @note Returns the value in Pascal(Pa)
+ * Output value of "96386" equals 96386 Pa =
+ * 963.86 hPa = 963.86 millibar
+ *
+ *
+ *
+ * @param v_uncomp_pressure_s32 : value of uncompensated pressure
+ *
+ *
+ *
+ * @return Return the actual pressure output as u32
+ *
+*/
+u32 bme280_compensate_P_int32(s32 v_uncomp_pressure_s32)
+{
+ s32 v_x1_u32 = BME280_ZERO_U8X;
+ s32 v_x2_u32 = BME280_ZERO_U8X;
+ u32 v_pressure_u32 = BME280_ZERO_U8X;
+
+ v_x1_u32 = (((s32)p_bme280->cal_param.t_fine)
+ >> SHIFT_RIGHT_1_POSITION) -
+ (s32)BME280_PRESSURE_6_4_0_0_0_DATA;
+ v_x2_u32 = (((v_x1_u32 >> SHIFT_RIGHT_2_POSITION)
+ * (v_x1_u32 >> SHIFT_RIGHT_2_POSITION))
+ >> SHIFT_RIGHT_11_POSITION) *
+ ((s32)p_bme280->cal_param.dig_P6);
+ v_x2_u32 = v_x2_u32 + ((v_x1_u32 *
+ ((s32)p_bme280->cal_param.dig_P5))
+ << SHIFT_LEFT_1_POSITION);
+ v_x2_u32 = (v_x2_u32 >> SHIFT_RIGHT_2_POSITION) +
+ (((s32)p_bme280->cal_param.dig_P4)
+ << SHIFT_LEFT_16_POSITION);
+ v_x1_u32 = (((p_bme280->cal_param.dig_P3
+ * (((v_x1_u32 >> SHIFT_RIGHT_2_POSITION) *
+ (v_x1_u32 >> SHIFT_RIGHT_2_POSITION))
+ >> SHIFT_RIGHT_13_POSITION)) >> SHIFT_RIGHT_3_POSITION) +
+ ((((s32)p_bme280->cal_param.dig_P2) *
+ v_x1_u32) >> SHIFT_RIGHT_1_POSITION))
+ >> SHIFT_RIGHT_18_POSITION;
+ v_x1_u32 = ((((BME280_PRESSURE_3_2_7_6_8_DATA + v_x1_u32)) *
+ ((s32)p_bme280->cal_param.dig_P1))
+ >> SHIFT_RIGHT_15_POSITION);
+ v_pressure_u32 =
+ (((u32)(((s32)BME280_PRESSURE_1_0_4_8_5_7_6_DATA)
+ - v_uncomp_pressure_s32) -
+ (v_x2_u32 >> SHIFT_RIGHT_12_POSITION)))
+ * BME280_PRESSURE_3_1_2_5_DATA;
+ if (v_pressure_u32
+ < BME280_HEX_PRESSURE_8_0_0_0_0_0_0_0_DATA)
+ /* Avoid exception caused by division by zero */
+ if (v_x1_u32 != BME280_ZERO_U8X)
+ v_pressure_u32 =
+ (v_pressure_u32 << SHIFT_LEFT_1_POSITION) /
+ ((u32)v_x1_u32);
+ else
+ return BME280_ZERO_U8X;
+ else
+ /* Avoid exception caused by division by zero */
+ if (v_x1_u32 != BME280_ZERO_U8X)
+ v_pressure_u32 = (v_pressure_u32
+ / (u32)v_x1_u32) * BME280_TWO_U8X;
+ else
+ return BME280_ZERO_U8X;
+
+ v_x1_u32 = (((s32)p_bme280->cal_param.dig_P9) *
+ ((s32)(((v_pressure_u32 >> SHIFT_RIGHT_3_POSITION)
+ * (v_pressure_u32 >> SHIFT_RIGHT_3_POSITION))
+ >> SHIFT_RIGHT_13_POSITION)))
+ >> SHIFT_RIGHT_12_POSITION;
+ v_x2_u32 = (((s32)(v_pressure_u32
+ >> SHIFT_RIGHT_2_POSITION)) *
+ ((s32)p_bme280->cal_param.dig_P8))
+ >> SHIFT_RIGHT_13_POSITION;
+ v_pressure_u32 = (u32)((s32)v_pressure_u32 +
+ ((v_x1_u32 + v_x2_u32 + p_bme280->cal_param.dig_P7)
+ >> SHIFT_RIGHT_4_POSITION));
+
+ return v_pressure_u32;
+}
+/*!
+ * @brief This API is used to read uncompensated humidity.
+ * in the registers 0xF7, 0xF8 and 0xF9
+ * @note 0xFD -> MSB -> bit from 0 to 7
+ * @note 0xFE -> LSB -> bit from 0 to 7
+ *
+ *
+ *
+ * @param v_uncomp_humidity_s32 : The value of uncompensated humidity
+ *
+ *
+ *
+ * @return results of bus communication function
+ * @retval 0 -> Success
+ * @retval -1 -> Error
+ *
+ *
+*/
+BME280_RETURN_FUNCTION_TYPE bme280_read_uncomp_humidity(
+s32 *v_uncomp_humidity_s32)
+{
+ /* used to return the communication result*/
+ BME280_RETURN_FUNCTION_TYPE com_rslt = ERROR;
+ /* Array holding the MSB and LSb value
+ a_data_u8[0] - Humidity MSB
+ a_data_u8[1] - Humidity LSB
+ */
+ u8 a_data_u8[ARRAY_SIZE_TWO] = {
+ BME280_ZERO_U8X, BME280_ZERO_U8X};
+ /* check the p_bme280 structure pointer as NULL*/
+ if (p_bme280 == BME280_NULL) {
+ return E_BME280_NULL_PTR;
+ } else {
+ com_rslt = p_bme280->BME280_BUS_READ_FUNC(
+ p_bme280->dev_addr,
+ BME280_HUMIDITY_MSB_REG, a_data_u8, BME280_TWO_U8X);
+ *v_uncomp_humidity_s32 = (s32)(
+ (((u32)(a_data_u8[INDEX_ZERO]))
+ << SHIFT_LEFT_8_POSITION)|
+ ((u32)(a_data_u8[INDEX_ONE])));
+ }
+ return com_rslt;
+}
+/*!
+ * @brief Reads actual humidity from uncompensated humidity
+ * @note Returns the value in %rH as unsigned 32bit integer
+ * in Q22.10 format(22 integer 10 fractional bits).
+ * @note An output value of 42313
+ * represents 42313 / 1024 = 41.321 %rH
+ *
+ *
+ *
+ * @param v_uncomp_humidity_s32: value of uncompensated humidity
+ *
+ * @return Return the actual relative humidity output as u32
+ *
+*/
+u32 bme280_compensate_H_int32(s32 v_uncomp_humidity_s32)
+{
+ s32 v_x1_u32;
+ v_x1_u32 = (p_bme280->cal_param.t_fine
+ - ((s32)BME280_HUMIDITY_7_6_8_0_0_DATA));
+ v_x1_u32 = (((((v_uncomp_humidity_s32
+ << SHIFT_LEFT_14_POSITION) -
+ (((s32)p_bme280->cal_param.dig_H4)
+ << SHIFT_LEFT_20_POSITION) -
+ (((s32)p_bme280->cal_param.dig_H5) * v_x1_u32)) +
+ ((s32)BME280_HUMIDITY_1_6_3_8_4_DATA))
+ >> SHIFT_RIGHT_15_POSITION) *
+ (((((((v_x1_u32 *
+ ((s32)p_bme280->cal_param.dig_H6))
+ >> SHIFT_RIGHT_10_POSITION) *
+ (((v_x1_u32 * ((s32)p_bme280->cal_param.dig_H3))
+ >> SHIFT_RIGHT_11_POSITION) +
+ ((s32)BME280_HUMIDITY_3_2_7_6_8_DATA)))
+ >> SHIFT_RIGHT_10_POSITION) +
+ ((s32)BME280_HUMIDITY_2_0_9_7_1_5_2_DATA)) *
+ ((s32)p_bme280->cal_param.dig_H2)
+ + BME280_HUMIDITY_8_1_9_2_DATA)
+ >> SHIFT_RIGHT_14_POSITION));
+ v_x1_u32 = (v_x1_u32 - (((((v_x1_u32
+ >> SHIFT_RIGHT_15_POSITION) *
+ (v_x1_u32 >> SHIFT_RIGHT_15_POSITION))
+ >> SHIFT_RIGHT_7_POSITION) *
+ ((s32)p_bme280->cal_param.dig_H1))
+ >> SHIFT_RIGHT_4_POSITION));
+ v_x1_u32 = (v_x1_u32 < BME280_ZERO_U8X
+ ? BME280_ZERO_U8X : v_x1_u32);
+ v_x1_u32 =
+ (v_x1_u32 > BME280_HUMIDITY_4_1_9_4_3_0_4_0_0_DATA ?
+ BME280_HUMIDITY_4_1_9_4_3_0_4_0_0_DATA : v_x1_u32);
+ return (u32)(v_x1_u32 >> SHIFT_RIGHT_12_POSITION);
+}
+/*!
+ * @brief Reads actual humidity from uncompensated humidity
+ * @note Returns the value in %rH as unsigned 16bit integer
+ * @note An output value of 42313
+ * represents 42313/512 = 82.643 %rH
+ *
+ *
+ *
+ * @param v_uncomp_humidity_s32: value of uncompensated humidity
+ *
+ *
+ * @return Return the actual relative humidity output as u16
+ *
+*/
+u16 bme280_compensate_H_int32_sixteen_bit_output(s32 v_uncomp_humidity_s32)
+{
+ u32 v_x1_u32;
+ u16 v_x2_u32;
+ v_x1_u32 = bme280_compensate_H_int32(v_uncomp_humidity_s32);
+ v_x2_u32 = (u16)(v_x1_u32 >> SHIFT_RIGHT_1_POSITION);
+ return v_x2_u32;
+}
+/*!
+ * @brief This API used to read uncompensated
+ * pressure,temperature and humidity
+ *
+ *
+ *
+ *
+ * @param v_uncomp_pressure_s32: The value of uncompensated pressure.
+ * @param v_uncomp_temperature_s32: The value of uncompensated temperature
+ * @param v_uncomp_humidity_s32: The value of uncompensated humidity.
+ *
+ *
+ *
+ * @return results of bus communication function
+ * @retval 0 -> Success
+ * @retval -1 -> Error
+ *
+ *
+*/
+BME280_RETURN_FUNCTION_TYPE bme280_read_uncomp_pressure_temperature_humidity(
+s32 *v_uncomp_pressure_s32,
+s32 *v_uncomp_temperature_s32, s32 *v_uncomp_humidity_s32)
+{
+ /* used to return the communication result*/
+ BME280_RETURN_FUNCTION_TYPE com_rslt = ERROR;
+ /* Array holding the MSB and LSb value of
+ a_data_u8[0] - Pressure MSB
+ a_data_u8[1] - Pressure LSB
+ a_data_u8[1] - Pressure LSB
+ a_data_u8[1] - Temperature MSB
+ a_data_u8[1] - Temperature LSB
+ a_data_u8[1] - Temperature LSB
+ a_data_u8[1] - Humidity MSB
+ a_data_u8[1] - Humidity LSB
+ */
+ u8 a_data_u8[ARRAY_SIZE_EIGHT] = {
+ BME280_ZERO_U8X, BME280_ZERO_U8X,
+ BME280_ZERO_U8X, BME280_ZERO_U8X,
+ BME280_ZERO_U8X, BME280_ZERO_U8X,
+ BME280_ZERO_U8X, BME280_ZERO_U8X};
+ /* check the p_bme280 structure pointer as NULL*/
+ if (p_bme280 == BME280_NULL) {
+ return E_BME280_NULL_PTR;
+ } else {
+ com_rslt = p_bme280->BME280_BUS_READ_FUNC(
+ p_bme280->dev_addr,
+ BME280_PRESSURE_MSB_REG,
+ a_data_u8, BME280_EIGHT_U8X);
+ /*Pressure*/
+ *v_uncomp_pressure_s32 = (s32)((
+ ((u32)(a_data_u8[INDEX_ZERO]))
+ << SHIFT_LEFT_12_POSITION) |
+ (((u32)(a_data_u8[INDEX_ONE]))
+ << SHIFT_LEFT_4_POSITION) |
+ ((u32)a_data_u8[INDEX_TWO] >>
+ SHIFT_RIGHT_4_POSITION));
+
+ /* Temperature */
+ *v_uncomp_temperature_s32 = (s32)(((
+ (u32) (a_data_u8[INDEX_THREE]))
+ << SHIFT_LEFT_12_POSITION) |
+ (((u32)(a_data_u8[INDEX_FOUR]))
+ << SHIFT_LEFT_4_POSITION)
+ | ((u32)a_data_u8[INDEX_FIVE]
+ >> SHIFT_RIGHT_4_POSITION));
+
+ /*Humidity*/
+ *v_uncomp_humidity_s32 = (s32)((
+ ((u32)(a_data_u8[INDEX_SIX]))
+ << SHIFT_LEFT_8_POSITION)|
+ ((u32)(a_data_u8[INDEX_SEVEN])));
+ }
+ return com_rslt;
+}
+/*!
+ * @brief This API used to read true pressure, temperature and humidity
+ *
+ *
+ *
+ *
+ * @param v_pressure_u32 : The value of compensated pressure.
+ * @param v_temperature_s32 : The value of compensated temperature.
+ * @param v_humidity_u32 : The value of compensated humidity.
+ *
+ *
+ * @return results of bus communication function
+ * @retval 0 -> Success
+ * @retval -1 -> Error
+ *
+ *
+*/
+BME280_RETURN_FUNCTION_TYPE bme280_read_pressure_temperature_humidity(
+u32 *v_pressure_u32, s32 *v_temperature_s32, u32 *v_humidity_u32)
+{
+ /* used to return the communication result*/
+ BME280_RETURN_FUNCTION_TYPE com_rslt = ERROR;
+ s32 v_uncomp_pressure_s32 = BME280_ZERO_U8X;
+ s32 v_uncom_temperature_s32 = BME280_ZERO_U8X;
+ s32 v_uncom_humidity_s32 = BME280_ZERO_U8X;
+ /* check the p_bme280 structure pointer as NULL*/
+ if (p_bme280 == BME280_NULL) {
+ return E_BME280_NULL_PTR;
+ } else {
+ /* read the uncompensated pressure,
+ temperature and humidity*/
+ com_rslt =
+ bme280_read_uncomp_pressure_temperature_humidity(
+ &v_uncomp_pressure_s32, &v_uncom_temperature_s32,
+ &v_uncom_humidity_s32);
+ /* read the true pressure, temperature and humidity*/
+ *v_temperature_s32 = bme280_compensate_T_int32(
+ v_uncom_temperature_s32);
+ *v_pressure_u32 = bme280_compensate_P_int32(
+ v_uncomp_pressure_s32);
+ *v_humidity_u32 = bme280_compensate_H_int32(
+ v_uncom_humidity_s32);
+ }
+ return com_rslt;
+}
+/*!
+ * @brief This API is used to
+ * calibration parameters used for calculation in the registers
+ *
+ * parameter | Register address | bit
+ *------------|------------------|----------------
+ * dig_T1 | 0x88 and 0x89 | from 0 : 7 to 8: 15
+ * dig_T2 | 0x8A and 0x8B | from 0 : 7 to 8: 15
+ * dig_T3 | 0x8C and 0x8D | from 0 : 7 to 8: 15
+ * dig_P1 | 0x8E and 0x8F | from 0 : 7 to 8: 15
+ * dig_P2 | 0x90 and 0x91 | from 0 : 7 to 8: 15
+ * dig_P3 | 0x92 and 0x93 | from 0 : 7 to 8: 15
+ * dig_P4 | 0x94 and 0x95 | from 0 : 7 to 8: 15
+ * dig_P5 | 0x96 and 0x97 | from 0 : 7 to 8: 15
+ * dig_P6 | 0x98 and 0x99 | from 0 : 7 to 8: 15
+ * dig_P7 | 0x9A and 0x9B | from 0 : 7 to 8: 15
+ * dig_P8 | 0x9C and 0x9D | from 0 : 7 to 8: 15
+ * dig_P9 | 0x9E and 0x9F | from 0 : 7 to 8: 15
+ * dig_H1 | 0xA1 | from 0 to 7
+ * dig_H2 | 0xE1 and 0xE2 | from 0 : 7 to 8: 15
+ * dig_H3 | 0xE3 | from 0 to 7
+ *
+ * @return results of bus communication function
+ * @retval 0 -> Success
+ * @retval -1 -> Error
+ *
+ *
+*/
+BME280_RETURN_FUNCTION_TYPE bme280_get_calib_param()
+{
+ /* used to return the communication result*/
+ BME280_RETURN_FUNCTION_TYPE com_rslt = ERROR;
+ u8 a_data_u8[ARRAY_SIZE_TWENTY_SIX] = {
+ BME280_ZERO_U8X, BME280_ZERO_U8X,
+ BME280_ZERO_U8X, BME280_ZERO_U8X, BME280_ZERO_U8X,
+ BME280_ZERO_U8X, BME280_ZERO_U8X, BME280_ZERO_U8X,
+ BME280_ZERO_U8X, BME280_ZERO_U8X, BME280_ZERO_U8X,
+ BME280_ZERO_U8X, BME280_ZERO_U8X, BME280_ZERO_U8X,
+ BME280_ZERO_U8X, BME280_ZERO_U8X, BME280_ZERO_U8X,
+ BME280_ZERO_U8X, BME280_ZERO_U8X, BME280_ZERO_U8X,
+ BME280_ZERO_U8X, BME280_ZERO_U8X, BME280_ZERO_U8X,
+ BME280_ZERO_U8X, BME280_ZERO_U8X, BME280_ZERO_U8X};
+ /* check the p_bme280 structure pointer as NULL*/
+ if (p_bme280 == BME280_NULL) {
+ return E_BME280_NULL_PTR;
+ } else {
+ com_rslt = p_bme280->BME280_BUS_READ_FUNC(
+ p_bme280->dev_addr,
+ BME280_DIG_T1_LSB_REG,
+ a_data_u8, BME280_TWENTY_SIX_U8X);
+
+ p_bme280->cal_param.dig_T1 = (u16)(((
+ (u16)((u8)a_data_u8[INDEX_ONE])) <<
+ SHIFT_LEFT_8_POSITION) | a_data_u8[INDEX_ZERO]);
+ p_bme280->cal_param.dig_T2 = (s16)(((
+ (s16)((s8)a_data_u8[INDEX_THREE])) <<
+ SHIFT_LEFT_8_POSITION) | a_data_u8[INDEX_TWO]);
+ p_bme280->cal_param.dig_T3 = (s16)(((
+ (s16)((s8)a_data_u8[INDEX_FIVE])) <<
+ SHIFT_LEFT_8_POSITION) | a_data_u8[INDEX_FOUR]);
+ p_bme280->cal_param.dig_P1 = (u16)(((
+ (u16)((u8)a_data_u8[INDEX_SEVEN])) <<
+ SHIFT_LEFT_8_POSITION) | a_data_u8[INDEX_SIX]);
+ p_bme280->cal_param.dig_P2 = (s16)(((
+ (s16)((s8)a_data_u8[INDEX_NINE])) <<
+ SHIFT_LEFT_8_POSITION) | a_data_u8[INDEX_EIGHT]);
+ p_bme280->cal_param.dig_P3 = (s16)(((
+ (s16)((s8)a_data_u8[INDEX_ELEVEN])) <<
+ SHIFT_LEFT_8_POSITION) | a_data_u8[INDEX_TEN]);
+ p_bme280->cal_param.dig_P4 = (s16)(((
+ (s16)((s8)a_data_u8[INDEX_THIRTEEN])) <<
+ SHIFT_LEFT_8_POSITION) | a_data_u8[INDEX_TWELVE]);
+ p_bme280->cal_param.dig_P5 = (s16)(((
+ (s16)((s8)a_data_u8[INDEX_FIVETEEN])) <<
+ SHIFT_LEFT_8_POSITION) | a_data_u8[INDEX_FOURTEEN]);
+ p_bme280->cal_param.dig_P6 = (s16)(((
+ (s16)((s8)a_data_u8[INDEX_SEVENTEEN])) <<
+ SHIFT_LEFT_8_POSITION) | a_data_u8[INDEX_SIXTEEN]);
+ p_bme280->cal_param.dig_P7 = (s16)(((
+ (s16)((s8)a_data_u8[INDEX_NINETEEN])) <<
+ SHIFT_LEFT_8_POSITION) | a_data_u8[INDEX_EIGHTEEN]);
+ p_bme280->cal_param.dig_P8 = (s16)(((
+ (s16)((s8)a_data_u8[INDEX_TWENTY_ONE])) <<
+ SHIFT_LEFT_8_POSITION) | a_data_u8[INDEX_TWENTY]);
+ p_bme280->cal_param.dig_P9 = (s16)(((
+ (s16)((s8)a_data_u8[INDEX_TWENTY_THREE])) <<
+ SHIFT_LEFT_8_POSITION) | a_data_u8[INDEX_TWENTY_TWO]);
+ p_bme280->cal_param.dig_H1 =
+ a_data_u8[INDEX_TWENTY_FIVE];
+ com_rslt += p_bme280->BME280_BUS_READ_FUNC(
+ p_bme280->dev_addr,
+ BME280_DIG_H2_LSB_REG, a_data_u8, BME280_SEVEN_U8X);
+ p_bme280->cal_param.dig_H2 = (s16)(((
+ (s16)((s8)a_data_u8[INDEX_ONE])) <<
+ SHIFT_LEFT_8_POSITION) | a_data_u8[INDEX_ZERO]);
+ p_bme280->cal_param.dig_H3 = a_data_u8[INDEX_TWO];
+ p_bme280->cal_param.dig_H4 = (s16)(((
+ (s16)((s8)a_data_u8[INDEX_THREE])) <<
+ SHIFT_LEFT_4_POSITION) |
+ (((u8)BME280_HEX_CALIB_0_F_DATA)
+ & a_data_u8[INDEX_FOUR]));
+ p_bme280->cal_param.dig_H5 = (s16)(((
+ (s16)((s8)a_data_u8[INDEX_FIVE])) <<
+ SHIFT_LEFT_4_POSITION) | (a_data_u8[INDEX_FOUR] >>
+ SHIFT_RIGHT_4_POSITION));
+ p_bme280->cal_param.dig_H6 = (s8)a_data_u8[INDEX_SIX];
+ }
+ return com_rslt;
+}
+/*!
+ * @brief This API is used to get
+ * the temperature oversampling setting in the register 0xF4
+ * bits from 5 to 7
+ *
+ * value | Temperature oversampling
+ * ---------------------|---------------------------------
+ * 0x00 | Skipped
+ * 0x01 | BME280_OVERSAMP_1X
+ * 0x02 | BME280_OVERSAMP_2X
+ * 0x03 | BME280_OVERSAMP_4X
+ * 0x04 | BME280_OVERSAMP_8X
+ * 0x05,0x06 and 0x07 | BME280_OVERSAMP_16X
+ *
+ *
+ * @param v_value_u8 : The value of temperature over sampling
+ *
+ *
+ *
+ * @return results of bus communication function
+ * @retval 0 -> Success
+ * @retval -1 -> Error
+ *
+ *
+*/
+BME280_RETURN_FUNCTION_TYPE bme280_get_oversamp_temperature(
+u8 *v_value_u8)
+{
+ /* used to return the communication result*/
+ BME280_RETURN_FUNCTION_TYPE com_rslt = ERROR;
+ u8 v_data_u8 = BME280_ZERO_U8X;
+ /* check the p_bme280 structure pointer as NULL*/
+ if (p_bme280 == BME280_NULL) {
+ return E_BME280_NULL_PTR;
+ } else {
+ com_rslt = p_bme280->BME280_BUS_READ_FUNC(
+ p_bme280->dev_addr,
+ BME280_CTRL_MEAS_REG_OVERSAMP_TEMPERATURE__REG,
+ &v_data_u8, BME280_ONE_U8X);
+ *v_value_u8 = BME280_GET_BITSLICE(v_data_u8,
+ BME280_CTRL_MEAS_REG_OVERSAMP_TEMPERATURE);
+
+ p_bme280->oversamp_temperature = *v_value_u8;
+ }
+ return com_rslt;
+}
+/*!
+ * @brief This API is used to set
+ * the temperature oversampling setting in the register 0xF4
+ * bits from 5 to 7
+ *
+ * value | Temperature oversampling
+ * ---------------------|---------------------------------
+ * 0x00 | Skipped
+ * 0x01 | BME280_OVERSAMP_1X
+ * 0x02 | BME280_OVERSAMP_2X
+ * 0x03 | BME280_OVERSAMP_4X
+ * 0x04 | BME280_OVERSAMP_8X
+ * 0x05,0x06 and 0x07 | BME280_OVERSAMP_16X
+ *
+ *
+ * @param v_value_u8 : The value of temperature over sampling
+ *
+ *
+ *
+ * @return results of bus communication function
+ * @retval 0 -> Success
+ * @retval -1 -> Error
+ *
+ *
+*/
+BME280_RETURN_FUNCTION_TYPE bme280_set_oversamp_temperature(
+u8 v_value_u8)
+{
+ /* used to return the communication result*/
+ BME280_RETURN_FUNCTION_TYPE com_rslt = ERROR;
+ u8 v_data_u8 = BME280_ZERO_U8X;
+ u8 v_prev_pow_mode_u8 = BME280_ZERO_U8X;
+ u8 v_pre_ctrl_hum_value_u8 = BME280_ZERO_U8X;
+ u8 v_pre_config_value_u8 = BME280_ZERO_U8X;
+ /* check the p_bme280 structure pointer as NULL*/
+ if (p_bme280 == BME280_NULL) {
+ return E_BME280_NULL_PTR;
+ } else {
+ v_data_u8 = p_bme280->ctrl_meas_reg;
+ v_data_u8 =
+ BME280_SET_BITSLICE(v_data_u8,
+ BME280_CTRL_MEAS_REG_OVERSAMP_TEMPERATURE, v_value_u8);
+ com_rslt = bme280_get_power_mode(&v_prev_pow_mode_u8);
+ if (v_prev_pow_mode_u8 != BME280_SLEEP_MODE) {
+ com_rslt += bme280_set_soft_rst();
+ p_bme280->delay_msec(BME280_3MS_DELAY);
+ /* write previous value
+ of configuration register*/
+ v_pre_config_value_u8 = p_bme280->config_reg;
+ com_rslt += bme280_write_register(
+ BME280_CONFIG_REG,
+ &v_pre_config_value_u8, BME280_ONE_U8X);
+ /* write previous value
+ of humidity oversampling*/
+ v_pre_ctrl_hum_value_u8 =
+ p_bme280->ctrl_hum_reg;
+ com_rslt += bme280_write_register(
+ BME280_CTRL_HUMIDITY_REG,
+ &v_pre_ctrl_hum_value_u8, BME280_ONE_U8X);
+ /* write previous and updated value
+ of configuration register*/
+ com_rslt += bme280_write_register(
+ BME280_CTRL_MEAS_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ } else {
+ com_rslt = p_bme280->BME280_BUS_WRITE_FUNC(
+ p_bme280->dev_addr,
+ BME280_CTRL_MEAS_REG_OVERSAMP_TEMPERATURE__REG,
+ &v_data_u8, BME280_ONE_U8X);
+ }
+ p_bme280->oversamp_temperature = v_value_u8;
+ /* read the control measurement register value*/
+ com_rslt = bme280_read_register(
+ BME280_CTRL_MEAS_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ p_bme280->ctrl_meas_reg = v_data_u8;
+ /* read the control humidity register value*/
+ com_rslt += bme280_read_register(
+ BME280_CTRL_HUMIDITY_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ p_bme280->ctrl_hum_reg = v_data_u8;
+ /* read the control
+ configuration register value*/
+ com_rslt += bme280_read_register(
+ BME280_CONFIG_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ p_bme280->config_reg = v_data_u8;
+ }
+ return com_rslt;
+}
+/*!
+ * @brief This API is used to get
+ * the pressure oversampling setting in the register 0xF4
+ * bits from 2 to 4
+ *
+ * value | Pressure oversampling
+ * --------------------|--------------------------
+ * 0x00 | Skipped
+ * 0x01 | BME280_OVERSAMP_1X
+ * 0x02 | BME280_OVERSAMP_2X
+ * 0x03 | BME280_OVERSAMP_4X
+ * 0x04 | BME280_OVERSAMP_8X
+ * 0x05,0x06 and 0x07 | BME280_OVERSAMP_16X
+ *
+ *
+ * @param v_value_u8 : The value of pressure oversampling
+ *
+ *
+ *
+ * @return results of bus communication function
+ * @retval 0 -> Success
+ * @retval -1 -> Error
+ *
+ *
+*/
+BME280_RETURN_FUNCTION_TYPE bme280_get_oversamp_pressure(
+u8 *v_value_u8)
+{
+ /* used to return the communication result*/
+ BME280_RETURN_FUNCTION_TYPE com_rslt = ERROR;
+ u8 v_data_u8 = BME280_ZERO_U8X;
+ /* check the p_bme280 structure pointer as NULL*/
+ if (p_bme280 == BME280_NULL) {
+ return E_BME280_NULL_PTR;
+ } else {
+ com_rslt = p_bme280->BME280_BUS_READ_FUNC(
+ p_bme280->dev_addr,
+ BME280_CTRL_MEAS_REG_OVERSAMP_PRESSURE__REG,
+ &v_data_u8, BME280_ONE_U8X);
+ *v_value_u8 = BME280_GET_BITSLICE(
+ v_data_u8,
+ BME280_CTRL_MEAS_REG_OVERSAMP_PRESSURE);
+
+ p_bme280->oversamp_pressure = *v_value_u8;
+ }
+ return com_rslt;
+}
+/*!
+ * @brief This API is used to set
+ * the pressure oversampling setting in the register 0xF4
+ * bits from 2 to 4
+ *
+ * value | Pressure oversampling
+ * --------------------|--------------------------
+ * 0x00 | Skipped
+ * 0x01 | BME280_OVERSAMP_1X
+ * 0x02 | BME280_OVERSAMP_2X
+ * 0x03 | BME280_OVERSAMP_4X
+ * 0x04 | BME280_OVERSAMP_8X
+ * 0x05,0x06 and 0x07 | BME280_OVERSAMP_16X
+ *
+ *
+ * @param v_value_u8 : The value of pressure oversampling
+ *
+ *
+ *
+ * @return results of bus communication function
+ * @retval 0 -> Success
+ * @retval -1 -> Error
+ *
+ *
+*/
+BME280_RETURN_FUNCTION_TYPE bme280_set_oversamp_pressure(
+u8 v_value_u8)
+{
+ /* used to return the communication result*/
+ BME280_RETURN_FUNCTION_TYPE com_rslt = ERROR;
+ u8 v_data_u8 = BME280_ZERO_U8X;
+ u8 v_prev_pow_mode_u8 = BME280_ZERO_U8X;
+ u8 v_pre_ctrl_hum_value_u8 = BME280_ZERO_U8X;
+ u8 v_pre_config_value_u8 = BME280_ZERO_U8X;
+ /* check the p_bme280 structure pointer as NULL*/
+ if (p_bme280 == BME280_NULL) {
+ return E_BME280_NULL_PTR;
+ } else {
+ v_data_u8 = p_bme280->ctrl_meas_reg;
+ v_data_u8 =
+ BME280_SET_BITSLICE(v_data_u8,
+ BME280_CTRL_MEAS_REG_OVERSAMP_PRESSURE, v_value_u8);
+ com_rslt = bme280_get_power_mode(&v_prev_pow_mode_u8);
+ if (v_prev_pow_mode_u8 != BME280_SLEEP_MODE) {
+ com_rslt += bme280_set_soft_rst();
+ p_bme280->delay_msec(BME280_3MS_DELAY);
+ /* write previous value of
+ configuration register*/
+ v_pre_config_value_u8 = p_bme280->config_reg;
+ com_rslt = bme280_write_register(
+ BME280_CONFIG_REG,
+ &v_pre_config_value_u8, BME280_ONE_U8X);
+ /* write previous value of
+ humidity oversampling*/
+ v_pre_ctrl_hum_value_u8 =
+ p_bme280->ctrl_hum_reg;
+ com_rslt += bme280_write_register(
+ BME280_CTRL_HUMIDITY_REG,
+ &v_pre_ctrl_hum_value_u8, BME280_ONE_U8X);
+ /* write previous and updated value of
+ control measurement register*/
+ bme280_write_register(
+ BME280_CTRL_MEAS_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ } else {
+ com_rslt = p_bme280->BME280_BUS_WRITE_FUNC(
+ p_bme280->dev_addr,
+ BME280_CTRL_MEAS_REG_OVERSAMP_PRESSURE__REG,
+ &v_data_u8, BME280_ONE_U8X);
+ }
+ p_bme280->oversamp_pressure = v_value_u8;
+ /* read the control measurement register value*/
+ com_rslt = bme280_read_register(
+ BME280_CTRL_MEAS_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ p_bme280->ctrl_meas_reg = v_data_u8;
+ /* read the control humidity register value*/
+ com_rslt += bme280_read_register(
+ BME280_CTRL_HUMIDITY_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ p_bme280->ctrl_hum_reg = v_data_u8;
+ /* read the control
+ configuration register value*/
+ com_rslt += bme280_read_register(
+ BME280_CONFIG_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ p_bme280->config_reg = v_data_u8;
+ }
+ return com_rslt;
+}
+/*!
+ * @brief This API is used to get
+ * the humidity oversampling setting in the register 0xF2
+ * bits from 0 to 2
+ *
+ * value | Humidity oversampling
+ * ---------------------|-------------------------
+ * 0x00 | Skipped
+ * 0x01 | BME280_OVERSAMP_1X
+ * 0x02 | BME280_OVERSAMP_2X
+ * 0x03 | BME280_OVERSAMP_4X
+ * 0x04 | BME280_OVERSAMP_8X
+ * 0x05,0x06 and 0x07 | BME280_OVERSAMP_16X
+ *
+ *
+ * @param v_value_u8 : The value of humidity over sampling
+ *
+ *
+ *
+ * @return results of bus communication function
+ * @retval 0 -> Success
+ * @retval -1 -> Error
+ *
+ *
+*/
+BME280_RETURN_FUNCTION_TYPE bme280_get_oversamp_humidity(
+u8 *v_value_u8)
+{
+ /* used to return the communication result*/
+ BME280_RETURN_FUNCTION_TYPE com_rslt = ERROR;
+ u8 v_data_u8 = BME280_ZERO_U8X;
+ /* check the p_bme280 structure pointer as NULL*/
+ if (p_bme280 == BME280_NULL) {
+ return E_BME280_NULL_PTR;
+ } else {
+ com_rslt = p_bme280->BME280_BUS_READ_FUNC(
+ p_bme280->dev_addr,
+ BME280_CTRL_HUMIDITY_REG_OVERSAM_HUMIDITY__REG,
+ &v_data_u8, BME280_ONE_U8X);
+ *v_value_u8 = BME280_GET_BITSLICE(
+ v_data_u8,
+ BME280_CTRL_HUMIDITY_REG_OVERSAM_HUMIDITY);
+
+ p_bme280->oversamp_humidity = *v_value_u8;
+ }
+ return com_rslt;
+}
+/*!
+ * @brief This API is used to set
+ * the humidity oversampling setting in the register 0xF2
+ * bits from 0 to 2
+ *
+ * value | Humidity oversampling
+ * ---------------------|-------------------------
+ * 0x00 | Skipped
+ * 0x01 | BME280_OVERSAMP_1X
+ * 0x02 | BME280_OVERSAMP_2X
+ * 0x03 | BME280_OVERSAMP_4X
+ * 0x04 | BME280_OVERSAMP_8X
+ * 0x05,0x06 and 0x07 | BME280_OVERSAMP_16X
+ *
+ *
+ * @param v_value_u8 : The value of humidity over sampling
+ *
+ *
+ *
+ * @note The "BME280_CTRL_HUMIDITY_REG_OVERSAM_HUMIDITY"
+ * register sets the humidity
+ * data acquisition options of the device.
+ * @note changes to this registers only become
+ * effective after a write operation to
+ * "BME280_CTRL_MEAS_REG" register.
+ * @note In the code automated reading and writing of
+ * "BME280_CTRL_HUMIDITY_REG_OVERSAM_HUMIDITY"
+ * @note register first set the
+ * "BME280_CTRL_HUMIDITY_REG_OVERSAM_HUMIDITY"
+ * and then read and write
+ * the "BME280_CTRL_MEAS_REG" register in the function.
+ *
+ *
+ * @return results of bus communication function
+ * @retval 0 -> Success
+ * @retval -1 -> Error
+ *
+ *
+*/
+BME280_RETURN_FUNCTION_TYPE bme280_set_oversamp_humidity(
+u8 v_value_u8)
+{
+ /* used to return the communication result*/
+ BME280_RETURN_FUNCTION_TYPE com_rslt = ERROR;
+ u8 v_data_u8 = BME280_ZERO_U8X;
+ u8 pre_ctrl_meas_value = BME280_ZERO_U8X;
+ u8 v_pre_config_value_u8 = BME280_ZERO_U8X;
+ u8 v_prev_pow_mode_u8 = BME280_ZERO_U8X;
+ /* check the p_bme280 structure pointer as NULL*/
+ if (p_bme280 == BME280_NULL) {
+ return E_BME280_NULL_PTR;
+ } else {
+ /* write humidity oversampling*/
+ v_data_u8 = p_bme280->ctrl_hum_reg;
+ v_data_u8 =
+ BME280_SET_BITSLICE(v_data_u8,
+ BME280_CTRL_HUMIDITY_REG_OVERSAM_HUMIDITY, v_value_u8);
+ com_rslt = bme280_get_power_mode(&v_prev_pow_mode_u8);
+ if (v_prev_pow_mode_u8 != BME280_SLEEP_MODE) {
+ com_rslt += bme280_set_soft_rst();
+ p_bme280->delay_msec(BME280_3MS_DELAY);
+ /* write previous value of
+ configuration register*/
+ v_pre_config_value_u8 = p_bme280->config_reg;
+ com_rslt += bme280_write_register(
+ BME280_CONFIG_REG,
+ &v_pre_config_value_u8, BME280_ONE_U8X);
+ /* write the value of control humidity*/
+ com_rslt += bme280_write_register(
+ BME280_CTRL_HUMIDITY_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ /* write previous value of
+ control measurement register*/
+ pre_ctrl_meas_value =
+ p_bme280->ctrl_meas_reg;
+ com_rslt += bme280_write_register(
+ BME280_CTRL_MEAS_REG,
+ &pre_ctrl_meas_value, BME280_ONE_U8X);
+ } else {
+ com_rslt +=
+ p_bme280->BME280_BUS_WRITE_FUNC(
+ p_bme280->dev_addr,
+ BME280_CTRL_HUMIDITY_REG_OVERSAM_HUMIDITY__REG,
+ &v_data_u8, BME280_ONE_U8X);
+ /* Control humidity write will effective only
+ after the control measurement register*/
+ pre_ctrl_meas_value =
+ p_bme280->ctrl_meas_reg;
+ com_rslt += bme280_write_register(
+ BME280_CTRL_MEAS_REG,
+ &pre_ctrl_meas_value, BME280_ONE_U8X);
+ }
+ p_bme280->oversamp_humidity = v_value_u8;
+ /* read the control measurement register value*/
+ com_rslt += bme280_read_register(BME280_CTRL_MEAS_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ p_bme280->ctrl_meas_reg = v_data_u8;
+ /* read the control humidity register value*/
+ com_rslt += bme280_read_register(
+ BME280_CTRL_HUMIDITY_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ p_bme280->ctrl_hum_reg = v_data_u8;
+ /* read the control configuration register value*/
+ com_rslt += bme280_read_register(BME280_CONFIG_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ p_bme280->config_reg = v_data_u8;
+ }
+ return com_rslt;
+}
+/*!
+ * @brief This API used to get the
+ * Operational Mode from the sensor in the register 0xF4 bit 0 and 1
+ *
+ *
+ *
+ * @param v_power_mode_u8 : The value of power mode
+ * value | mode
+ * -----------------|------------------
+ * 0x00 | BME280_SLEEP_MODE
+ * 0x01 and 0x02 | BME280_FORCED_MODE
+ * 0x03 | BME280_NORMAL_MODE
+ *
+ * @return results of bus communication function
+ * @retval 0 -> Success
+ * @retval -1 -> Error
+ *
+ *
+*/
+BME280_RETURN_FUNCTION_TYPE bme280_get_power_mode(u8 *v_power_mode_u8)
+{
+ /* used to return the communication result*/
+ BME280_RETURN_FUNCTION_TYPE com_rslt = ERROR;
+ u8 v_mode_u8r = BME280_ZERO_U8X;
+ /* check the p_bme280 structure pointer as NULL*/
+ if (p_bme280 == BME280_NULL) {
+ return E_BME280_NULL_PTR;
+ } else {
+ com_rslt = p_bme280->BME280_BUS_READ_FUNC(
+ p_bme280->dev_addr,
+ BME280_CTRL_MEAS_REG_POWER_MODE__REG,
+ &v_mode_u8r, BME280_ONE_U8X);
+ *v_power_mode_u8 = BME280_GET_BITSLICE(v_mode_u8r,
+ BME280_CTRL_MEAS_REG_POWER_MODE);
+ }
+ return com_rslt;
+}
+/*!
+ * @brief This API used to set the
+ * Operational Mode from the sensor in the register 0xF4 bit 0 and 1
+ *
+ *
+ *
+ * @param v_power_mode_u8 : The value of power mode
+ * value | mode
+ * -----------------|------------------
+ * 0x00 | BME280_SLEEP_MODE
+ * 0x01 and 0x02 | BME280_FORCED_MODE
+ * 0x03 | BME280_NORMAL_MODE
+ *
+ * @return results of bus communication function
+ * @retval 0 -> Success
+ * @retval -1 -> Error
+ *
+ *
+*/
+BME280_RETURN_FUNCTION_TYPE bme280_set_power_mode(u8 v_power_mode_u8)
+{
+ /* used to return the communication result*/
+ BME280_RETURN_FUNCTION_TYPE com_rslt = ERROR;
+ u8 v_mode_u8r = BME280_ZERO_U8X;
+ u8 v_prev_pow_mode_u8 = BME280_ZERO_U8X;
+ u8 v_pre_ctrl_hum_value_u8 = BME280_ZERO_U8X;
+ u8 v_pre_config_value_u8 = BME280_ZERO_U8X;
+ u8 v_data_u8 = BME280_ZERO_U8X;
+ /* check the p_bme280 structure pointer as NULL*/
+ if (p_bme280 == BME280_NULL) {
+ return E_BME280_NULL_PTR;
+ } else {
+ if (v_power_mode_u8 < BME280_FOUR_U8X) {
+ v_mode_u8r = p_bme280->ctrl_meas_reg;
+ v_mode_u8r =
+ BME280_SET_BITSLICE(v_mode_u8r,
+ BME280_CTRL_MEAS_REG_POWER_MODE,
+ v_power_mode_u8);
+ com_rslt = bme280_get_power_mode(
+ &v_prev_pow_mode_u8);
+ if (v_prev_pow_mode_u8 != BME280_SLEEP_MODE) {
+ com_rslt += bme280_set_soft_rst();
+ p_bme280->delay_msec(BME280_3MS_DELAY);
+ /* write previous value of
+ configuration register*/
+ v_pre_config_value_u8 =
+ p_bme280->config_reg;
+ com_rslt = bme280_write_register(
+ BME280_CONFIG_REG,
+ &v_pre_config_value_u8, BME280_ONE_U8X);
+ /* write previous value of
+ humidity oversampling*/
+ v_pre_ctrl_hum_value_u8 =
+ p_bme280->ctrl_hum_reg;
+ com_rslt += bme280_write_register(
+ BME280_CTRL_HUMIDITY_REG,
+ &v_pre_ctrl_hum_value_u8,
+ BME280_ONE_U8X);
+ /* write previous and updated value of
+ control measurement register*/
+ com_rslt += bme280_write_register(
+ BME280_CTRL_MEAS_REG,
+ &v_mode_u8r, BME280_ONE_U8X);
+ } else {
+ com_rslt =
+ p_bme280->BME280_BUS_WRITE_FUNC(
+ p_bme280->dev_addr,
+ BME280_CTRL_MEAS_REG_POWER_MODE__REG,
+ &v_mode_u8r, BME280_ONE_U8X);
+ }
+ /* read the control measurement register value*/
+ com_rslt = bme280_read_register(
+ BME280_CTRL_MEAS_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ p_bme280->ctrl_meas_reg = v_data_u8;
+ /* read the control humidity register value*/
+ com_rslt += bme280_read_register(
+ BME280_CTRL_HUMIDITY_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ p_bme280->ctrl_hum_reg = v_data_u8;
+ /* read the config register value*/
+ com_rslt += bme280_read_register(
+ BME280_CONFIG_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ p_bme280->config_reg = v_data_u8;
+ } else {
+ com_rslt = E_BME280_OUT_OF_RANGE;
+ }
+ }
+ return com_rslt;
+}
+/*!
+ * @brief Used to reset the sensor
+ * The value 0xB6 is written to the 0xE0
+ * register the device is reset using the
+ * complete power-on-reset procedure.
+ * @note Soft reset can be easily set using bme280_set_softreset().
+ * @note Usage Hint : bme280_set_softreset()
+ *
+ *
+ * @return results of bus communication function
+ * @retval 0 -> Success
+ * @retval -1 -> Error
+ *
+ *
+*/
+BME280_RETURN_FUNCTION_TYPE bme280_set_soft_rst()
+{
+ /* used to return the communication result*/
+ BME280_RETURN_FUNCTION_TYPE com_rslt = ERROR;
+ u8 v_data_u8 = BME280_SOFT_RESET_CODE;
+ /* check the p_bme280 structure pointer as NULL*/
+ if (p_bme280 == BME280_NULL) {
+ return E_BME280_NULL_PTR;
+ } else {
+ com_rslt = p_bme280->BME280_BUS_WRITE_FUNC(
+ p_bme280->dev_addr,
+ BME280_RST_REG, &v_data_u8, BME280_ONE_U8X);
+ }
+ return com_rslt;
+}
+/*!
+ * @brief This API used to get the sensor
+ * SPI mode(communication type) in the register 0xF5 bit 0
+ *
+ *
+ *
+ * @param v_enable_disable_u8 : The value of SPI enable
+ * value | Description
+ * --------|--------------
+ * 0 | Disable
+ * 1 | Enable
+ *
+ *
+ *
+ * @return results of bus communication function
+ * @retval 0 -> Success
+ * @retval -1 -> Error
+ *
+ *
+*/
+BME280_RETURN_FUNCTION_TYPE bme280_get_spi3(u8 *v_enable_disable_u8)
+{
+ /* used to return the communication result*/
+ BME280_RETURN_FUNCTION_TYPE com_rslt = ERROR;
+ u8 v_data_u8 = BME280_ZERO_U8X;
+ /* check the p_bme280 structure pointer as NULL*/
+ if (p_bme280 == BME280_NULL) {
+ return E_BME280_NULL_PTR;
+ } else {
+ com_rslt = p_bme280->BME280_BUS_READ_FUNC(
+ p_bme280->dev_addr,
+ BME280_CONFIG_REG_SPI3_ENABLE__REG,
+ &v_data_u8, BME280_ONE_U8X);
+ *v_enable_disable_u8 = BME280_GET_BITSLICE(
+ v_data_u8,
+ BME280_CONFIG_REG_SPI3_ENABLE);
+ }
+ return com_rslt;
+}
+/*!
+ * @brief This API used to set the sensor
+ * SPI mode(communication type) in the register 0xF5 bit 0
+ *
+ *
+ *
+ * @param v_enable_disable_u8 : The value of SPI enable
+ * value | Description
+ * --------|--------------
+ * 0 | Disable
+ * 1 | Enable
+ *
+ *
+ *
+ * @return results of bus communication function
+ * @retval 0 -> Success
+ * @retval -1 -> Error
+ *
+ *
+*/
+BME280_RETURN_FUNCTION_TYPE bme280_set_spi3(u8 v_enable_disable_u8)
+{
+ /* used to return the communication result*/
+ BME280_RETURN_FUNCTION_TYPE com_rslt = ERROR;
+ u8 v_data_u8 = BME280_ZERO_U8X;
+ u8 pre_ctrl_meas_value = BME280_ZERO_U8X;
+ u8 v_prev_pow_mode_u8 = BME280_ZERO_U8X;
+ u8 v_pre_ctrl_hum_value_u8 = BME280_ZERO_U8X;
+ /* check the p_bme280 structure pointer as NULL*/
+ if (p_bme280 == BME280_NULL) {
+ return E_BME280_NULL_PTR;
+ } else {
+ v_data_u8 = p_bme280->config_reg;
+ v_data_u8 =
+ BME280_SET_BITSLICE(v_data_u8,
+ BME280_CONFIG_REG_SPI3_ENABLE, v_enable_disable_u8);
+ com_rslt = bme280_get_power_mode(&v_prev_pow_mode_u8);
+ if (v_prev_pow_mode_u8 != BME280_SLEEP_MODE) {
+ com_rslt += bme280_set_soft_rst();
+ p_bme280->delay_msec(BME280_3MS_DELAY);
+ /* write previous and updated value of
+ configuration register*/
+ com_rslt += bme280_write_register(
+ BME280_CONFIG_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ /* write previous value of
+ humidity oversampling*/
+ v_pre_ctrl_hum_value_u8 =
+ p_bme280->ctrl_hum_reg;
+ com_rslt += bme280_write_register(
+ BME280_CTRL_HUMIDITY_REG,
+ &v_pre_ctrl_hum_value_u8, BME280_ONE_U8X);
+ /* write previous value of
+ control measurement register*/
+ pre_ctrl_meas_value =
+ p_bme280->ctrl_meas_reg;
+ com_rslt += bme280_write_register(
+ BME280_CTRL_MEAS_REG,
+ &pre_ctrl_meas_value, BME280_ONE_U8X);
+ } else {
+ com_rslt =
+ p_bme280->BME280_BUS_WRITE_FUNC(
+ p_bme280->dev_addr,
+ BME280_CONFIG_REG_SPI3_ENABLE__REG,
+ &v_data_u8, BME280_ONE_U8X);
+ }
+ /* read the control measurement register value*/
+ com_rslt += bme280_read_register(
+ BME280_CTRL_MEAS_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ p_bme280->ctrl_meas_reg = v_data_u8;
+ /* read the control humidity register value*/
+ com_rslt += bme280_read_register(
+ BME280_CTRL_HUMIDITY_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ p_bme280->ctrl_hum_reg = v_data_u8;
+ /* read the control configuration register value*/
+ com_rslt += bme280_read_register(
+ BME280_CONFIG_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ p_bme280->config_reg = v_data_u8;
+ }
+ return com_rslt;
+}
+/*!
+ * @brief This API is used to reads filter setting
+ * in the register 0xF5 bit 3 and 4
+ *
+ *
+ *
+ * @param v_value_u8 : The value of IIR filter coefficient
+ *
+ * value | Filter coefficient
+ * -------------|-------------------------
+ * 0x00 | BME280_FILTER_COEFF_OFF
+ * 0x01 | BME280_FILTER_COEFF_2
+ * 0x02 | BME280_FILTER_COEFF_4
+ * 0x03 | BME280_FILTER_COEFF_8
+ * 0x04 | BME280_FILTER_COEFF_16
+ *
+ * @return results of bus communication function
+ * @retval 0 -> Success
+ * @retval -1 -> Error
+ *
+ *
+*/
+BME280_RETURN_FUNCTION_TYPE bme280_get_filter(u8 *v_value_u8)
+{
+ /* used to return the communication result*/
+ BME280_RETURN_FUNCTION_TYPE com_rslt = ERROR;
+ u8 v_data_u8 = BME280_ZERO_U8X;
+ /* check the p_bme280 structure pointer as NULL*/
+ if (p_bme280 == BME280_NULL) {
+ return E_BME280_NULL_PTR;
+ } else {
+ com_rslt = p_bme280->BME280_BUS_READ_FUNC(
+ p_bme280->dev_addr,
+ BME280_CONFIG_REG_FILTER__REG,
+ &v_data_u8, BME280_ONE_U8X);
+ *v_value_u8 = BME280_GET_BITSLICE(v_data_u8,
+ BME280_CONFIG_REG_FILTER);
+ }
+ return com_rslt;
+}
+/*!
+ * @brief This API is used to write filter setting
+ * in the register 0xF5 bit 3 and 4
+ *
+ *
+ *
+ * @param v_value_u8 : The value of IIR filter coefficient
+ *
+ * value | Filter coefficient
+ * -------------|-------------------------
+ * 0x00 | BME280_FILTER_COEFF_OFF
+ * 0x01 | BME280_FILTER_COEFF_2
+ * 0x02 | BME280_FILTER_COEFF_4
+ * 0x03 | BME280_FILTER_COEFF_8
+ * 0x04 | BME280_FILTER_COEFF_16
+ *
+ * @return results of bus communication function
+ * @retval 0 -> Success
+ * @retval -1 -> Error
+ *
+ *
+*/
+BME280_RETURN_FUNCTION_TYPE bme280_set_filter(u8 v_value_u8)
+{
+ /* used to return the communication result*/
+ BME280_RETURN_FUNCTION_TYPE com_rslt = ERROR;
+ u8 v_data_u8 = BME280_ZERO_U8X;
+ u8 pre_ctrl_meas_value = BME280_ZERO_U8X;
+ u8 v_prev_pow_mode_u8 = BME280_ZERO_U8X;
+ u8 v_pre_ctrl_hum_value_u8 = BME280_ZERO_U8X;
+ /* check the p_bme280 structure pointer as NULL*/
+ if (p_bme280 == BME280_NULL) {
+ return E_BME280_NULL_PTR;
+ } else {
+ v_data_u8 = p_bme280->config_reg;
+ v_data_u8 =
+ BME280_SET_BITSLICE(v_data_u8,
+ BME280_CONFIG_REG_FILTER, v_value_u8);
+ com_rslt = bme280_get_power_mode(&v_prev_pow_mode_u8);
+ if (v_prev_pow_mode_u8 != BME280_SLEEP_MODE) {
+ com_rslt += bme280_set_soft_rst();
+ p_bme280->delay_msec(BME280_3MS_DELAY);
+ /* write previous and updated value of
+ configuration register*/
+ com_rslt += bme280_write_register(
+ BME280_CONFIG_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ /* write previous value of
+ humidity oversampling*/
+ v_pre_ctrl_hum_value_u8 =
+ p_bme280->ctrl_hum_reg;
+ com_rslt += bme280_write_register(
+ BME280_CTRL_HUMIDITY_REG,
+ &v_pre_ctrl_hum_value_u8, BME280_ONE_U8X);
+ /* write previous value of
+ control measurement register*/
+ pre_ctrl_meas_value =
+ p_bme280->ctrl_meas_reg;
+ com_rslt += bme280_write_register(
+ BME280_CTRL_MEAS_REG,
+ &pre_ctrl_meas_value, BME280_ONE_U8X);
+ } else {
+ com_rslt =
+ p_bme280->BME280_BUS_WRITE_FUNC(
+ p_bme280->dev_addr,
+ BME280_CONFIG_REG_FILTER__REG,
+ &v_data_u8, BME280_ONE_U8X);
+ }
+ /* read the control measurement register value*/
+ com_rslt += bme280_read_register(BME280_CTRL_MEAS_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ p_bme280->ctrl_meas_reg = v_data_u8;
+ /* read the control humidity register value*/
+ com_rslt += bme280_read_register(
+ BME280_CTRL_HUMIDITY_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ p_bme280->ctrl_hum_reg = v_data_u8;
+ /* read the configuration register value*/
+ com_rslt += bme280_read_register(BME280_CONFIG_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ p_bme280->config_reg = v_data_u8;
+ }
+ return com_rslt;
+}
+/*!
+ * @brief This API used to Read the
+ * standby duration time from the sensor in the register 0xF5 bit 5 to 7
+ *
+ * @param v_standby_durn_u8 : The value of standby duration time value.
+ * value | standby duration
+ * -------------|-----------------------
+ * 0x00 | BME280_STANDBY_TIME_1_MS
+ * 0x01 | BME280_STANDBY_TIME_63_MS
+ * 0x02 | BME280_STANDBY_TIME_125_MS
+ * 0x03 | BME280_STANDBY_TIME_250_MS
+ * 0x04 | BME280_STANDBY_TIME_500_MS
+ * 0x05 | BME280_STANDBY_TIME_1000_MS
+ * 0x06 | BME280_STANDBY_TIME_2000_MS
+ * 0x07 | BME280_STANDBY_TIME_4000_MS
+ *
+ *
+ * @return results of bus communication function
+ * @retval 0 -> Success
+ * @retval -1 -> Error
+ *
+ *
+*/
+BME280_RETURN_FUNCTION_TYPE bme280_get_standby_durn(u8 *v_standby_durn_u8)
+{
+ /* used to return the communication result*/
+ BME280_RETURN_FUNCTION_TYPE com_rslt = ERROR;
+ u8 v_data_u8 = BME280_ZERO_U8X;
+ /* check the p_bme280 structure pointer as NULL*/
+ if (p_bme280 == BME280_NULL) {
+ return E_BME280_NULL_PTR;
+ } else {
+ com_rslt = p_bme280->BME280_BUS_READ_FUNC(
+ p_bme280->dev_addr,
+ BME280_CONFIG_REG_TSB__REG,
+ &v_data_u8, BME280_ONE_U8X);
+ *v_standby_durn_u8 = BME280_GET_BITSLICE(
+ v_data_u8, BME280_CONFIG_REG_TSB);
+ }
+ return com_rslt;
+}
+/*!
+ * @brief This API used to write the
+ * standby duration time from the sensor in the register 0xF5 bit 5 to 7
+ *
+ * @param v_standby_durn_u8 : The value of standby duration time value.
+ * value | standby duration
+ * -------------|-----------------------
+ * 0x00 | BME280_STANDBY_TIME_1_MS
+ * 0x01 | BME280_STANDBY_TIME_63_MS
+ * 0x02 | BME280_STANDBY_TIME_125_MS
+ * 0x03 | BME280_STANDBY_TIME_250_MS
+ * 0x04 | BME280_STANDBY_TIME_500_MS
+ * 0x05 | BME280_STANDBY_TIME_1000_MS
+ * 0x06 | BME280_STANDBY_TIME_2000_MS
+ * 0x07 | BME280_STANDBY_TIME_4000_MS
+ *
+ * @note Normal mode comprises an automated perpetual
+ * cycling between an (active)
+ * Measurement period and an (inactive) standby period.
+ * @note The standby time is determined by
+ * the contents of the register t_sb.
+ * Standby time can be set using BME280_STANDBY_TIME_125_MS.
+ *
+ * @note Usage Hint : bme280_set_standby_durn(BME280_STANDBY_TIME_125_MS)
+ *
+ *
+ *
+ * @return results of bus communication function
+ * @retval 0 -> Success
+ * @retval -1 -> Error
+ *
+ *
+*/
+BME280_RETURN_FUNCTION_TYPE bme280_set_standby_durn(u8 v_standby_durn_u8)
+{
+ /* used to return the communication result*/
+ BME280_RETURN_FUNCTION_TYPE com_rslt = ERROR;
+ u8 v_data_u8 = BME280_ZERO_U8X;
+ u8 pre_ctrl_meas_value = BME280_ZERO_U8X;
+ u8 v_prev_pow_mode_u8 = BME280_ZERO_U8X;
+ u8 v_pre_ctrl_hum_value_u8 = BME280_ZERO_U8X;
+ /* check the p_bme280 structure pointer as NULL*/
+ if (p_bme280 == BME280_NULL) {
+ return E_BME280_NULL_PTR;
+ } else {
+ v_data_u8 = p_bme280->config_reg;
+ v_data_u8 =
+ BME280_SET_BITSLICE(v_data_u8,
+ BME280_CONFIG_REG_TSB, v_standby_durn_u8);
+ com_rslt = bme280_get_power_mode(&v_prev_pow_mode_u8);
+ if (v_prev_pow_mode_u8 != BME280_SLEEP_MODE) {
+ com_rslt += bme280_set_soft_rst();
+ p_bme280->delay_msec(BME280_3MS_DELAY);
+ /* write previous and updated value of
+ configuration register*/
+ com_rslt += bme280_write_register(
+ BME280_CONFIG_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ /* write previous value of
+ humidity oversampling*/
+ v_pre_ctrl_hum_value_u8 =
+ p_bme280->ctrl_hum_reg;
+ com_rslt += bme280_write_register(
+ BME280_CTRL_HUMIDITY_REG,
+ &v_pre_ctrl_hum_value_u8, BME280_ONE_U8X);
+ /* write previous value of control
+ measurement register*/
+ pre_ctrl_meas_value =
+ p_bme280->ctrl_meas_reg;
+ com_rslt += bme280_write_register(
+ BME280_CTRL_MEAS_REG,
+ &pre_ctrl_meas_value, BME280_ONE_U8X);
+ } else {
+ com_rslt =
+ p_bme280->BME280_BUS_WRITE_FUNC(
+ p_bme280->dev_addr,
+ BME280_CONFIG_REG_TSB__REG,
+ &v_data_u8, BME280_ONE_U8X);
+ }
+ /* read the control measurement register value*/
+ com_rslt += bme280_read_register(BME280_CTRL_MEAS_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ p_bme280->ctrl_meas_reg = v_data_u8;
+ /* read the control humidity register value*/
+ com_rslt += bme280_read_register(
+ BME280_CTRL_HUMIDITY_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ p_bme280->ctrl_hum_reg = v_data_u8;
+ /* read the configuration register value*/
+ com_rslt += bme280_read_register(BME280_CONFIG_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ p_bme280->config_reg = v_data_u8;
+ }
+ return com_rslt;
+}
+/*
+ * @brief Writes the working mode to the sensor
+ *
+ *
+ *
+ *
+ * @param v_work_mode_u8 : Mode to be set
+ * value | Working mode
+ * ----------|--------------------
+ * 0 | BME280_ULTRALOWPOWER_MODE
+ * 1 | BME280_LOWPOWER_MODE
+ * 2 | BME280_STANDARDRESOLUTION_MODE
+ * 3 | BME280_HIGHRESOLUTION_MODE
+ * 4 | BME280_ULTRAHIGHRESOLUTION_MODE
+ *
+ * @return results of bus communication function
+ * @retval 0 -> Success
+ * @retval -1 -> Error
+ *
+ *
+*/
+/*BME280_RETURN_FUNCTION_TYPE bme280_set_work_mode(u8 v_work_mode_u8)
+{
+BME280_RETURN_FUNCTION_TYPE com_rslt = ERROR;
+u8 v_data_u8 = BME280_ZERO_U8X;
+if (p_bme280 == BME280_NULL) {
+ return E_BME280_NULL_PTR;
+} else {
+ if (v_work_mode_u8 <= BME280_FOUR_U8X) {
+ com_rslt = p_bme280->BME280_BUS_READ_FUNC(
+ p_bme280->dev_addr, BME280_CTRL_MEAS_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ if (com_rslt == SUCCESS) {
+ switch (v_work_mode_u8) {
+ case BME280_ULTRALOWPOWER_MODE:
+ p_bme280->oversamp_temperature =
+ BME280_ULTRALOWPOWER_OSRS_T;
+ p_bme280->osrs_p =
+ BME280_ULTRALOWPOWER_OSRS_P;
+ break;
+ case BME280_LOWPOWER_MODE:
+ p_bme280->oversamp_temperature =
+ BME280_LOWPOWER_OSRS_T;
+ p_bme280->osrs_p = BME280_LOWPOWER_OSRS_P;
+ break;
+ case BME280_STANDARDRESOLUTION_MODE:
+ p_bme280->oversamp_temperature =
+ BME280_STANDARDRESOLUTION_OSRS_T;
+ p_bme280->osrs_p =
+ BME280_STANDARDRESOLUTION_OSRS_P;
+ break;
+ case BME280_HIGHRESOLUTION_MODE:
+ p_bme280->oversamp_temperature =
+ BME280_HIGHRESOLUTION_OSRS_T;
+ p_bme280->osrs_p = BME280_HIGHRESOLUTION_OSRS_P;
+ break;
+ case BME280_ULTRAHIGHRESOLUTION_MODE:
+ p_bme280->oversamp_temperature =
+ BME280_ULTRAHIGHRESOLUTION_OSRS_T;
+ p_bme280->osrs_p =
+ BME280_ULTRAHIGHRESOLUTION_OSRS_P;
+ break;
+ }
+ v_data_u8 = BME280_SET_BITSLICE(v_data_u8,
+ BME280_CTRL_MEAS_REG_OVERSAMP_TEMPERATURE,
+ p_bme280->oversamp_temperature);
+ v_data_u8 = BME280_SET_BITSLICE(v_data_u8,
+ BME280_CTRL_MEAS_REG_OVERSAMP_PRESSURE,
+ p_bme280->osrs_p);
+ com_rslt += p_bme280->BME280_BUS_WRITE_FUNC(
+ p_bme280->dev_addr, BME280_CTRL_MEAS_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ }
+ } else {
+ com_rslt = E_BME280_OUT_OF_RANGE;
+ }
+}
+return com_rslt;
+}*/
+/*!
+ * @brief This API used to read uncompensated
+ * temperature,pressure and humidity in forced mode
+ *
+ *
+ * @param v_uncom_pressure_s32: The value of uncompensated pressure
+ * @param v_uncom_temperature_s32: The value of uncompensated temperature
+ * @param v_uncom_humidity_s32: The value of uncompensated humidity
+ *
+ *
+ * @return results of bus communication function
+ * @retval 0 -> Success
+ * @retval -1 -> Error
+ *
+ *
+*/
+BME280_RETURN_FUNCTION_TYPE
+bme280_get_forced_uncomp_pressure_temperature_humidity(
+s32 *v_uncom_pressure_s32,
+s32 *v_uncom_temperature_s32, s32 *v_uncom_humidity_s32)
+{
+ /* used to return the communication result*/
+ BME280_RETURN_FUNCTION_TYPE com_rslt = ERROR;
+ u8 v_data_u8 = BME280_ZERO_U8X;
+ u8 v_waittime_u8r = BME280_ZERO_U8X;
+ u8 v_prev_pow_mode_u8 = BME280_ZERO_U8X;
+ u8 v_mode_u8r = BME280_ZERO_U8X;
+ u8 pre_ctrl_config_value = BME280_ZERO_U8X;
+ u8 v_pre_ctrl_hum_value_u8 = BME280_ZERO_U8X;
+ /* check the p_bme280 structure pointer as NULL*/
+ if (p_bme280 == BME280_NULL) {
+ return E_BME280_NULL_PTR;
+ } else {
+ v_mode_u8r = p_bme280->ctrl_meas_reg;
+ v_mode_u8r =
+ BME280_SET_BITSLICE(v_mode_u8r,
+ BME280_CTRL_MEAS_REG_POWER_MODE, BME280_FORCED_MODE);
+ com_rslt = bme280_get_power_mode(&v_prev_pow_mode_u8);
+ if (v_prev_pow_mode_u8 != BME280_SLEEP_MODE) {
+ com_rslt += bme280_set_soft_rst();
+ p_bme280->delay_msec(BME280_3MS_DELAY);
+ /* write previous and updated value of
+ configuration register*/
+ pre_ctrl_config_value = p_bme280->config_reg;
+ com_rslt += bme280_write_register(
+ BME280_CONFIG_REG,
+ &pre_ctrl_config_value, BME280_ONE_U8X);
+ /* write previous value of
+ humidity oversampling*/
+ v_pre_ctrl_hum_value_u8 =
+ p_bme280->ctrl_hum_reg;
+ com_rslt += bme280_write_register(
+ BME280_CTRL_HUMIDITY_REG,
+ &v_pre_ctrl_hum_value_u8, BME280_ONE_U8X);
+ /* write the force mode */
+ com_rslt += bme280_write_register(
+ BME280_CTRL_MEAS_REG,
+ &v_mode_u8r, BME280_ONE_U8X);
+ } else {
+ /* write previous value of
+ humidity oversampling*/
+ v_pre_ctrl_hum_value_u8 =
+ p_bme280->ctrl_hum_reg;
+ com_rslt += bme280_write_register(
+ BME280_CTRL_HUMIDITY_REG,
+ &v_pre_ctrl_hum_value_u8, BME280_ONE_U8X);
+ /* write the force mode */
+ com_rslt += bme280_write_register(
+ BME280_CTRL_MEAS_REG,
+ &v_mode_u8r, BME280_ONE_U8X);
+ }
+ bme280_compute_wait_time(&v_waittime_u8r);
+ p_bme280->delay_msec(v_waittime_u8r);
+ /* read the force-mode value of pressure
+ temperature and humidity*/
+ com_rslt +=
+ bme280_read_uncomp_pressure_temperature_humidity(
+ v_uncom_pressure_s32, v_uncom_temperature_s32,
+ v_uncom_humidity_s32);
+
+ /* read the control humidity register value*/
+ com_rslt += bme280_read_register(
+ BME280_CTRL_HUMIDITY_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ p_bme280->ctrl_hum_reg = v_data_u8;
+ /* read the configuration register value*/
+ com_rslt += bme280_read_register(BME280_CONFIG_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ p_bme280->config_reg = v_data_u8;
+
+ /* read the control measurement register value*/
+ com_rslt += bme280_read_register(BME280_CTRL_MEAS_REG,
+ &v_data_u8, BME280_ONE_U8X);
+ p_bme280->ctrl_meas_reg = v_data_u8;
+ }
+ return com_rslt;
+}
+/*!
+ * @brief
+ * This API write the data to
+ * the given register
+ *
+ *
+ * @param v_addr_u8 -> Address of the register
+ * @param v_data_u8 -> The data from the register
+ * @param v_len_u8 -> no of bytes to read
+ *
+ *
+ * @return results of bus communication function
+ * @retval 0 -> Success
+ * @retval -1 -> Error
+ *
+ *
+ */
+BME280_RETURN_FUNCTION_TYPE bme280_write_register(u8 v_addr_u8,
+u8 *v_data_u8, u8 v_len_u8)
+{
+ /* used to return the communication result*/
+ BME280_RETURN_FUNCTION_TYPE com_rslt = ERROR;
+ /* check the p_bme280 structure pointer as NULL*/
+ if (p_bme280 == BME280_NULL) {
+ return E_BME280_NULL_PTR;
+ } else {
+ com_rslt = p_bme280->BME280_BUS_WRITE_FUNC(
+ p_bme280->dev_addr,
+ v_addr_u8, v_data_u8, v_len_u8);
+ }
+ return com_rslt;
+}
+/*!
+ * @brief
+ * This API reads the data from
+ * the given register
+ *
+ *
+ * @param v_addr_u8 -> Address of the register
+ * @param v_data_u8 -> The data from the register
+ * @param v_len_u8 -> no of bytes to read
+ *
+ *
+ * @return results of bus communication function
+ * @retval 0 -> Success
+ * @retval -1 -> Error
+ *
+ *
+ */
+BME280_RETURN_FUNCTION_TYPE bme280_read_register(u8 v_addr_u8,
+u8 *v_data_u8, u8 v_len_u8)
+{
+ /* used to return the communication result*/
+ BME280_RETURN_FUNCTION_TYPE com_rslt = ERROR;
+ /* check the p_bme280 structure pointer as NULL*/
+ if (p_bme280 == BME280_NULL) {
+ return E_BME280_NULL_PTR;
+ } else {
+ com_rslt = p_bme280->BME280_BUS_READ_FUNC(
+ p_bme280->dev_addr,
+ v_addr_u8, v_data_u8, v_len_u8);
+ }
+ return com_rslt;
+}
+#ifdef BME280_ENABLE_FLOAT
+/*!
+ * @brief Reads actual temperature from uncompensated temperature
+ * @note returns the value in Degree centigrade
+ * @note Output value of "51.23" equals 51.23 DegC.
+ *
+ *
+ *
+ * @param v_uncom_temperature_s32 : value of uncompensated temperature
+ *
+ *
+ *
+ * @return Return the actual temperature in floating point
+ *
+*/
+double bme280_compensate_T_double(s32 v_uncom_temperature_s32)
+{
+ double v_x1_u32 = BME280_ZERO_U8X;
+ double v_x2_u32 = BME280_ZERO_U8X;
+ double temperature = BME280_ZERO_U8X;
+
+ v_x1_u32 = (((double)v_uncom_temperature_s32)
+ / BME280_FLOAT_TRUE_TEMP_1_6_3_8_4_DATA -
+ ((double)p_bme280->cal_param.dig_T1)
+ / BME280_FLOAT_TRUE_TEMP_1_0_2_4_DATA) *
+ ((double)p_bme280->cal_param.dig_T2);
+ v_x2_u32 = ((((double)v_uncom_temperature_s32)
+ / BME280_FLOAT_TRUE_TEMP_1_3_1_0_7_2_DATA -
+ ((double)p_bme280->cal_param.dig_T1)
+ / BME280_FLOAT_TRUE_TEMP_8_1_9_2_DATA) *
+ (((double)v_uncom_temperature_s32) /
+ BME280_FLOAT_TRUE_TEMP_1_3_1_0_7_2_DATA -
+ ((double)p_bme280->cal_param.dig_T1) /
+ BME280_FLOAT_TRUE_TEMP_8_1_9_2_DATA)) *
+ ((double)p_bme280->cal_param.dig_T3);
+ p_bme280->cal_param.t_fine = (s32)(v_x1_u32 + v_x2_u32);
+ temperature = (v_x1_u32 + v_x2_u32) /
+ BME280_FLOAT_TRUE_TEMP_5_1_2_0_DATA;
+
+
+ return temperature;
+}
+/*!
+ * @brief Reads actual pressure from uncompensated pressure
+ * @note Returns pressure in Pa as double.
+ * @note Output value of "96386.2"
+ * equals 96386.2 Pa = 963.862 hPa.
+ *
+ *
+ * @param v_uncom_pressure_s32 : value of uncompensated pressure
+ *
+ *
+ * @return Return the actual pressure in floating point
+ *
+*/
+double bme280_compensate_P_double(s32 v_uncom_pressure_s32)
+{
+ double v_x1_u32 = BME280_ZERO_U8X;
+ double v_x2_u32 = BME280_ZERO_U8X;
+ double pressure = BME280_ZERO_U8X;
+
+ v_x1_u32 = ((double)p_bme280->cal_param.t_fine /
+ BME280_FLAOT_TRUE_PRESSURE_2_DATA) -
+ BME280_FLAOT_TRUE_PRESSURE_6_4_0_0_0_DATA;
+ v_x2_u32 = v_x1_u32 * v_x1_u32 *
+ ((double)p_bme280->cal_param.dig_P6) /
+ BME280_FLAOT_TRUE_PRESSURE_3_2_7_6_8_DATA;
+ v_x2_u32 = v_x2_u32 + v_x1_u32 *
+ ((double)p_bme280->cal_param.dig_P5) *
+ BME280_FLAOT_TRUE_PRESSURE_2_DATA;
+ v_x2_u32 = (v_x2_u32 / BME280_FLAOT_TRUE_PRESSURE_4_DATA) +
+ (((double)p_bme280->cal_param.dig_P4) *
+ BME280_FLAOT_TRUE_PRESSURE_6_5_5_3_6_DATA);
+ v_x1_u32 = (((double)p_bme280->cal_param.dig_P3) *
+ v_x1_u32 * v_x1_u32
+ / BME280_FLAOT_TRUE_PRESSURE_5_2_4_2_8_8_DATA +
+ ((double)p_bme280->cal_param.dig_P2) * v_x1_u32) /
+ BME280_FLAOT_TRUE_PRESSURE_5_2_4_2_8_8_DATA;
+ v_x1_u32 = (BME280_FLAOT_TRUE_PRESSURE_1_DATA + v_x1_u32
+ / BME280_FLAOT_TRUE_PRESSURE_3_2_7_6_8_DATA) *
+ ((double)p_bme280->cal_param.dig_P1);
+ pressure = BME280_FLAOT_TRUE_PRESSURE_1_0_4_8_5_7_6_DATA
+ - (double)v_uncom_pressure_s32;
+ /* Avoid exception caused by division by zero */
+ if (v_x1_u32 != BME280_ZERO_U8X)
+ pressure = (pressure - (v_x2_u32
+ / BME280_FLAOT_TRUE_PRESSURE_4_0_9_6_DATA))
+ * BME280_FLAOT_TRUE_PRESSURE_6_2_5_0_DATA / v_x1_u32;
+ else
+ return BME280_ZERO_U8X;
+ v_x1_u32 = ((double)p_bme280->cal_param.dig_P9) *
+ pressure * pressure /
+ BME280_FLAOT_TRUE_PRESSURE_2_1_4_7_4_8_3_6_4_8_DATA;
+ v_x2_u32 = pressure * ((double)p_bme280->cal_param.dig_P8)
+ / BME280_FLAOT_TRUE_PRESSURE_3_2_7_6_8_DATA;
+ pressure = pressure + (v_x1_u32 + v_x2_u32 +
+ ((double)p_bme280->cal_param.dig_P7))
+ / BME280_FLAOT_TRUE_PRESSURE_1_6_DATA;
+
+ return pressure;
+}
+/*!
+ * @brief Reads actual humidity from uncompensated humidity
+ * @note returns the value in relative humidity (%rH)
+ * @note Output value of "42.12" equals 42.12 %rH
+ *
+ * @param v_uncom_humidity_s32 : value of uncompensated humidity
+ *
+ *
+ *
+ * @return Return the actual humidity in floating point
+ *
+*/
+double bme280_compensate_H_double(s32 v_uncom_humidity_s32)
+{
+ double var_h = BME280_ZERO_U8X;
+ var_h = (((double)p_bme280->cal_param.t_fine)
+ - BME280_TRUE_HUMIDITY_7_6_8_0_0_DATA);
+ if (var_h != BME280_ZERO_U8X)
+ var_h = (v_uncom_humidity_s32 -
+ (((double)p_bme280->cal_param.dig_H4)
+ * BME280_TRUE_HUMIDITY_6_4_DATA +
+ ((double)p_bme280->cal_param.dig_H5)
+ / BME280_TRUE_HUMIDITY_1_6_3_8_4_DATA * var_h))*
+ (((double)p_bme280->cal_param.dig_H2)
+ /BME280_TRUE_HUMIDITY_6_5_5_3_6_DATA *
+ (BME280_TRUE_HUMIDITY_1_DATA + ((double)
+ p_bme280->cal_param.dig_H6)
+ / BME280_TRUE_HUMIDITY_6_7_1_0_8_8_6_4_DATA
+ * var_h * (BME280_TRUE_HUMIDITY_1_DATA + ((double)
+ p_bme280->cal_param.dig_H3)
+ / BME280_TRUE_HUMIDITY_6_7_1_0_8_8_6_4_DATA * var_h)));
+ else
+ return BME280_ZERO_U8X;
+ var_h = var_h * (BME280_TRUE_HUMIDITY_1_DATA - ((double)
+ p_bme280->cal_param.dig_H1)*var_h
+ / BME280_TRUE_HUMIDITY_5_2_4_2_8_8_DATA);
+ if (var_h > BME280_TRUE_HUMIDITY_1_0_0_DATA)
+ var_h = BME280_TRUE_HUMIDITY_1_0_0_DATA;
+ else if (var_h < BME280_TRUE_HUMIDITY_0_DATA)
+ var_h = BME280_TRUE_HUMIDITY_0_DATA;
+ return var_h;
+
+}
+#endif
+#if defined(BME280_ENABLE_INT64) && defined(BME280_64BITSUPPORT_PRESENT)
+/*!
+ * @brief Reads actual pressure from uncompensated pressure
+ * @note Returns the value in Pa as unsigned 32 bit
+ * integer in Q24.8 format (24 integer bits and
+ * 8 fractional bits).
+ * @note Output value of "24674867"
+ * represents 24674867 / 256 = 96386.2 Pa = 963.862 hPa
+ *
+ *
+ *
+ * @param v_uncom_pressure_s32 : value of uncompensated temperature
+ *
+ *
+ * @return Return the actual pressure in u32
+ *
+*/
+u32 bme280_compensate_P_int64(s32 v_uncom_pressure_s32)
+{
+ s64 v_x1_s64r = BME280_ZERO_U8X;
+ s64 v_x2_s64r = BME280_ZERO_U8X;
+ s64 pressure = BME280_ZERO_U8X;
+ v_x1_s64r = ((s64)p_bme280->cal_param.t_fine)
+ - BME280_TRUE_PRESSURE_1_2_8_0_0_0_DATA;
+ v_x2_s64r = v_x1_s64r * v_x1_s64r *
+ (s64)p_bme280->cal_param.dig_P6;
+ v_x2_s64r = v_x2_s64r + ((v_x1_s64r *
+ (s64)p_bme280->cal_param.dig_P5)
+ << SHIFT_LEFT_17_POSITION);
+ v_x2_s64r = v_x2_s64r +
+ (((s64)p_bme280->cal_param.dig_P4)
+ << SHIFT_LEFT_35_POSITION);
+ v_x1_s64r = ((v_x1_s64r * v_x1_s64r *
+ (s64)p_bme280->cal_param.dig_P3)
+ >> SHIFT_RIGHT_8_POSITION) +
+ ((v_x1_s64r * (s64)p_bme280->cal_param.dig_P2)
+ << SHIFT_LEFT_12_POSITION);
+ v_x1_s64r = (((((s64)BME280_ONE_U8X)
+ << SHIFT_LEFT_47_POSITION) + v_x1_s64r)) *
+ ((s64)p_bme280->cal_param.dig_P1)
+ >> SHIFT_RIGHT_33_POSITION;
+ pressure = BME280_TRUE_PRESSURE_1_0_4_8_5_7_6_DATA
+ - v_uncom_pressure_s32;
+ /* Avoid exception caused by division by zero */
+ if (v_x1_s64r != BME280_ZERO_U8X)
+ #if defined __KERNEL__
+ pressure = div64_s64((((pressure
+ << SHIFT_LEFT_31_POSITION) - v_x2_s64r)
+ * BME280_TRUE_PRESSURE_3_1_2_5_DATA),
+ v_x1_s64r);
+ #else
+ pressure = (((pressure
+ << SHIFT_LEFT_31_POSITION) - v_x2_s64r)
+ * BME280_TRUE_PRESSURE_3_1_2_5_DATA) / v_x1_s64r;
+ #endif
+ else
+ return BME280_ZERO_U8X;
+ v_x1_s64r = (((s64)p_bme280->cal_param.dig_P9) *
+ (pressure >> SHIFT_RIGHT_13_POSITION) *
+ (pressure >> SHIFT_RIGHT_13_POSITION))
+ >> SHIFT_RIGHT_25_POSITION;
+ v_x2_s64r = (((s64)p_bme280->cal_param.dig_P8) *
+ pressure) >> SHIFT_RIGHT_19_POSITION;
+ pressure = (((pressure + v_x1_s64r +
+ v_x2_s64r) >> SHIFT_RIGHT_8_POSITION) +
+ (((s64)p_bme280->cal_param.dig_P7)
+ << SHIFT_LEFT_4_POSITION));
+
+ return (u32)pressure;
+}
+/*!
+ * @brief Reads actual pressure from uncompensated pressure
+ * @note Returns the value in Pa.
+ * @note Output value of "12337434"
+ * @note represents 12337434 / 128 = 96386.2 Pa = 963.862 hPa
+ *
+ *
+ *
+ * @param v_uncom_pressure_s32 : value of uncompensated pressure
+ *
+ *
+ * @return the actual pressure in u32
+ *
+*/
+u32 bme280_compensate_P_int64_twentyfour_bit_output(s32 v_uncom_pressure_s32)
+{
+ u32 pressure = BME280_ZERO_U8X;
+ pressure = bme280_compensate_P_int64(v_uncom_pressure_s32);
+ pressure = (u32)(pressure >> SHIFT_RIGHT_1_POSITION);
+ return pressure;
+}
+#endif
+/*!
+ * @brief Computing waiting time for sensor data read
+ *
+ *
+ *
+ *
+ * @param v_delaytime_u8 : The value of delay time for force mode
+ *
+ *
+ * @retval 0 -> Success
+ *
+ *
+ */
+BME280_RETURN_FUNCTION_TYPE bme280_compute_wait_time(u8
+*v_delaytime_u8)
+{
+ /* used to return the communication result*/
+ BME280_RETURN_FUNCTION_TYPE com_rslt = SUCCESS;
+
+ *v_delaytime_u8 = (T_INIT_MAX +
+ T_MEASURE_PER_OSRS_MAX *
+ (((BME280_ONE_U8X
+ << p_bme280->oversamp_temperature)
+ >> SHIFT_RIGHT_1_POSITION) +
+ ((BME280_ONE_U8X << p_bme280->oversamp_pressure)
+ >> SHIFT_RIGHT_1_POSITION) +
+ ((BME280_ONE_U8X << p_bme280->oversamp_humidity)
+ >> SHIFT_RIGHT_1_POSITION))+
+ (p_bme280->oversamp_pressure ?
+ T_SETUP_PRESSURE_MAX : BME280_ZERO_U8X) +
+ (p_bme280->oversamp_humidity ?
+ T_SETUP_HUMIDITY_MAX : BME280_ZERO_U8X)
+ + BME280_FIVETEEN_U8X) / BME280_SIXTEEN_U8X;
+ return com_rslt;
+}